The Investigation of Dosimetric Potentials of Surgical Face Masks Using Electron Spin Resonance Spectroscopy

Loading...
Publication Logo

Date

2025-04-21

Authors

Karaaslan, Hulya

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Wien

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

Research Projects

Journal Issue

Abstract

In this study, the Electron Spin Resonance (ESR) dosimetric potential of surgical face masks was investigated within the intermediate gamma dose range of 0.05-10 kGy. White, blue, and green mask samples were used for this analysis. FTIR and XRD analyses confirmed that all masks were made of polypropylene. No ESR signals were detected in the unirradiated masks. However, in gamma-irradiated samples, resonance signal components at g & Vert;=2.031 +/- 0.002\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${g}_{\parallel }= 2.031 \pm 0.002$$\end{document} and g perpendicular to=2.007 +/- 0.002\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${g}_{\perp }= 2.007 \pm 0.002$$\end{document}, associated with peroxy radicals (RO2<middle dot>), were observed, with the intensity of the g perpendicular to=2.007 +/- 0.002\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${g}_{\perp }= 2.007 \pm 0.002$$\end{document} signal increasing exponentially within the investigated dose range. Despite the decrease in radiation-induced signal intensities at room temperature, surgical masks can be considered as emergency dosimeters when other materials suitable for dose estimation are unavailable.

Description

Keywords

Fields of Science

Citation

WoS Q

Q4

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Applied Magnetic Resonance

Volume

56

Issue

7

Start Page

859

End Page

870
PlumX Metrics
Citations

Scopus : 0

Page Views

1

checked on Apr 29, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.0

Sustainable Development Goals