Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14365/3621
Title: Design of a New System for Upper Extremity Movement Ability Assessment
Other Titles: Ust Ekstremite Hareket Kabiliyeti Degerlendirmesi Icin Yeni Bir Sistem Tasarimi
Authors: Cizmeciogullari S.
Kocak M.
Mihcin S.
Tosun A.
Akan A.
Keywords: elbow
measurement
repeatibility
ROM
shoulder
validity
Cameras
Camera systems
Goniometric measurements
Interval of confidence
Kinect cameras
Range of motions
Upper extremity
Upper extremity functions
Upper extremity movements
Signal processing
Publisher: Institute of Electrical and Electronics Engineers Inc.
Abstract: One of the methods used in upper extremity function assessment is the Range of Motion (ROM) measurements. In practice, these measurements are performed by a clinicians' personal observations and/or goniometric measurements. In these measurements, there are some problems related to repeatibility and reliability criterias. In this study, a novel system which contains only a single camera to perform ROM calculations objectively in upper extremity is suggested. For this purpose shoulder and elbow flexion movements were recorded and analyzed. The system was compared with which was known as a 'Gold Standard' system. The nine male and nine female volunteers were participated in the study. Kinect camera was used to record movements of upper limb. The Kinect camera results were compared with that of OptiTrack camera system. The shoulder and elbow flexion angles were computed for both systems. The agreement between the two systems were examined statistically by using the computed ROM values. Bland-Altman plots revealed the agreement within 95 % interval of confidence, between the two systems for shoulder flexion and elbow flexion in both males and females. This study provides evidence for the suitability of the proposed system for a clinical work. © 2020 IEEE.
Description: 28th Signal Processing and Communications Applications Conference, SIU 2020 -- 5 October 2020 through 7 October 2020 -- 166413
URI: https://doi.org/10.1109/SIU49456.2020.9302514
https://hdl.handle.net/20.500.14365/3621
ISBN: 9.78173E+12
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
2712.pdf
  Restricted Access
510.45 kBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

Page view(s)

84
checked on Nov 18, 2024

Download(s)

6
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.