Title: Effect of Column-to-Beam Strength Ratio Distribution on the Seismic Behavior of Reinforced Concrete Frame Structures
Authors: Sondilek, F.
Sönmez, E.
Taşlıgedik, A.Ş.
Keywords: Drift distribution
Seismic design
Strong column-weak beam
Reinforced concrete
Seismic response
Static analysis
Structural frames
Beam strength
Drift distribution
Moment frames
Reinforced concrete frame structures
Seismic behaviour
Seismic design code
Seismic forces
Story mechanisms
Strength ratios
Strong column weak beam
Seismic design
Publisher: Yumurtacı Hüseyinoğlu I.Ö.
Abstract: Seismic design codes are the standards that provide resistance for the structures against the potential seismic forces that the structure may face. One of the provisions in the seismic design codes is the strong column-weak beam (SCWB) requirement. It suggests that at that the sum of the flexural strength of the columns at a joint should be greater than those of the beams at the same joint. This requirement aims to prevent column yielding during an earthquake and avoid story mechanisms in moment frames. Although the seismic design codes suggest a minimum column-to-beam strength ratio, previous research has shown that this ratio may not be sufficient to provide desired collapse mechanisms for all conditions. Also, it has been observed that the column-to-beam strength ratio distribution along the height of the frame structures affects the understory and damage distribution. This study investigated the effect of different column-to-beam strength ratio distributions on the drift distribution of the reinforced concrete moment frames. For this purpose, different frames were considered with different numbers of stories and bays. OpenSeesPy framework was used for numerical modeling. To evaluate the seismic response of the model frames, nonlinear time history, and nonlinear static analyses were used. The results showed that the column-to-beam strength ratio distribution significantly affects the distribution of inter-story drift ratios. An effective column-to-beam strength ratio distribution was proposed at the end of the study. © The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd. 2024.
Description: ACE 2023,6 September 2023 through 8 September 2023,,312069,23662557,9789819717804,,,English,Lect. Notes Civ. Eng.,Conference Paper,Final,",Scopus,2-s2.0-85193582293 Polater A.
Kingshott R.P.J. -- Schepis D.,56348787200;57195374268;23501593700;56040672000;,Drivers of geographical indication food supply chain performance: a B2B network perspective,2024,Journal of Business and Industrial Marketing,,,,",",,,10.1108/JBIM-06-2023-0313,https://www.scopus.com/inward/record.uri?eid=2-s2.0-85193488785&doi=10.1108%2fJBIM-06-2023-0313&partnerID=40&md5=63ea96de10467028a3fb90170813d53f,A.C.Ç School of Civil Aviation -- Erzincan Binali Yildirim University
URI: https://doi.org/10.1007/978-981-97-1781-1_27
https://hdl.handle.net/20.500.14365/5356
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Show full item record



CORE Recommender

Page view(s)

82
checked on Sep 30, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.