Repository logoGCRIS
  • English
  • Türkçe
  • Русский
Log In
New user? Click here to register. Have you forgotten your password?
Home
Communities
Browse GCRIS
Entities
Overview
GCRIS Guide
  1. Home
  2. Browse by Author

Browsing by Author "Akdag, Murat"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Article
    Citation - WoS: 2
    Citation - Scopus: 2
    Active Vibration Control of Cantilever Structures by Integrating the Closed Loop Control Action Into Transient Solution of Finite Element Model and an Application To Aircraft Wing
    (Mdpi, 2025) Bulbul, Ilker; Akdag, Murat; Karagulle, Hira
    In this study, the active vibration control (AVC) of a cantilever beam with an end mass is considered first and studied experimentally and through simulation. The Laplace transform method, Newmark method, and ANSYS are used for simulations. An impulse force applied to the mass and the velocity actuation applied to the base are assumed to be disturbance and controlling input, respectively. The displacement of the mass is taken as the feedback signal in simulations. Four strain gauges are located near the bottom point, connected with a Wheatstone bridge, and the output voltage of a load-cell amplifier (LCA) is used as the feedback signal in experiments. Strain feedback is considered in experiments because it is easy to implement, cost-effective, and can be used in applications. Experimental displacement signals obtained from the top of the beam are compared with the output signals from LCA and it is observed that they are approximately linearly dependent. Velocity input is generated with a servo motor-driven linear actuator in experiments. The closed loop control is achieved by a personal computer with an Adlink-9222 PCI DAQ card and a C program in the experiments. The integration of the closed loop control action into the transient solution with Newmark method and ANSYS is implemented in simulations. The input reference value is taken as zero for vibration control. The instantaneous value of the feedback signal at a time step is subtracted from zero to find the error signal value and the error value is multiplied by the control gain to calculate the controlling signal. The simulation results obtained with the Newmark method and ANSYS are in good agreement with the analytical results obtained with Laplace transform method. Simulation results are also in acceptable agreement with the experimental results for explaining the behavior of the success of AVC depending on the control gain, Kp. After verifying ANSYS solutions, the ANSYS procedure is applied to an aircraft wing as a real complex cantilever structure. The wing, with a length of 810.8 mm, 13 ribs with a length of 300 mm, and NACA 4412 airfoil, is considered in this study. It is observed that the AVC of real engineering structures can be simulated by integrating control action into transient solution in ANSYS.
Repository logo
Collections
  • Scopus Collection
  • WoS Collection
  • TrDizin Collection
  • PubMed Collection
Entities
  • Research Outputs
  • Organizations
  • Researchers
  • Projects
  • Awards
  • Equipments
  • Events
About
  • Contact
  • GCRIS
  • Research Ecosystems
  • Feedback
  • OAI-PMH

Log in to GCRIS Dashboard

GCRIS Mobile

Download GCRIS Mobile on the App StoreGet GCRIS Mobile on Google Play

Powered by Research Ecosystems

  • Privacy policy
  • End User Agreement
  • Feedback