Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14365/1089
Title: Hand gesture classification using time-frequency images and transfer learning based on CNN
Authors: Ozdemir, Mehmet Akif
Kisa, Deniz Hande
Guren, Onan
Akan, Aydin
Keywords: Hand Gesture Classification
Convolutional Neural Networks (CNN)
Electromyogram (EMG)
STFT
CWT
Hilbert-Huang Transform (HHT)
Hilbert Spectrum
Emg
Recognition
Publisher: Elsevier Sci Ltd
Abstract: Hand gesture-based systems are one of the most effective technological advances and continue to develop with improvements in the field of human-computer interaction. Surface electromyography (sEMG) is utilized as a popular input data for gesture classification with elevated accuracy and advanced control capability. This paper presents a comparative hand gesture classification approach using time-frequency (TF) images of the spontaneous sEMG signals and the transfer learning method. 4-channel sEMG signals are collected from 30 subjects performing 7 specific hand gestures. After the required pre-processing, segmentation, and windowing steps, three TF analysis methods, namely Short-Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT), and Hilbert-Huang Transform (HHT), are applied to EMG signals to obtain TF images. Spectrograms from STFT, scalograms from CWT, and Hilbert-Huang spectra (HHS) from HHT obtained from multi-channel sEMG data are separately fused. TF images are then utilized to extract distinct features using seven state-of-the-art, pre-trained Convolutional Neural Network (CNN) architectures and classify seven hand gestures. Two different robust crossvalidation strategies are conducted to evaluate the proposed method; stratified k-fold cross-validation (SKCV) and leave-one-subject-out cross-validation (LOOCV). We also investigate the effect of window size and the combination of Intrinsic Mode Functions (IMFs) on classification performance. The results demonstrated that the HHT utilizing IMFs obtained by Empirical Mode Decomposition (EMD) provided improved TF resolution and better results than STFT and CWT in the classification of sEMG signals. Finally, the best average accuracies (93.75% for SKCV) and (94.41% for LOOCV) are obtained by the HHT method with the pre-trained ResNet-50 model.
URI: https://doi.org/10.1016/j.bspc.2022.103787
https://hdl.handle.net/20.500.14365/1089
ISSN: 1746-8094
1746-8108
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
99.pdf
  Restricted Access
6.04 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

47
checked on Sep 18, 2024

WEB OF SCIENCETM
Citations

37
checked on Sep 18, 2024

Page view(s)

74
checked on Aug 19, 2024

Download(s)

4
checked on Aug 19, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.