Title: Quantitative evaluation of the damage to RC buildings caused by the 2023 southeast Turkey earthquake sequence
Authors: Pujol, S.
Bedirhanoglu, I.
Donmez, C.
Dowgala, J.D.
Eryilmaz-Yildirim, M.
Klaboe, K.
Koroglu, F.B.
Sönmez, Egemen
Keywords: column index
drift
nonstructural damage
peak ground velocity
Priority index
wall index
Building codes
Concrete buildings
Earthquakes
Structural analysis
Walls (structural partitions)
Column index
Drift
Earthquake sequences
Non-structural damage
Peak ground velocity
Priority index
Quantitative evaluation
Seismic drift
Structural walls
Wall index
Reinforced concrete
Publisher: SAGE Publications Inc.
Abstract: Data from 15 earthquakes that occurred in 12 different countries are presented showing that, without better drift control, structures built with building codes allowing large seismic drifts are likely to keep leaving a wide wake of damage ranging from cracked partitions to building overturning. Following the earthquake sequence affecting southeast Turkey in 2023, a team led by Committee 133 of the American Concrete Institute surveyed nearly 250 reinforced concrete buildings in the area extending from Antakya to Malatya. Buildings ranging from 2 to 16 stories were surveyed to assess their damage and evaluate the robustness of their structures in relation to overall stiffness, as measured by the relative cross-sectional areas of structural walls and columns. The majority of the buildings were estimated to have been built in the past 10 years. Yet, the structures surveyed were observed to have amounts of structural walls and columns comparable with amounts reported after the Erzincan (1992), Duzce (1999), and Bingol (2003) Earthquakes in Turkey. These amounts are, on average, much smaller than the wall and column amounts used in Chile and Japan. Because of that lack of robustness and given the intensities of the motions reported from Antakya to Malatya (with 10 stations with peak ground velocity (PGV) of 100 cm/s or more), it is concluded that structures in this region experienced large drifts. Excessive drift (1) exposed a myriad of construction and detailing problems leading to severe structural damage and collapse, (2) induced overturning caused by p-delta for some buildings, and (3) caused widespread damage to brittle masonry partitions. The main lesson is simple: ductility is necessary but not sufficient. It is urgent that seismic drift limits are tightened in high-seismicity regions worldwide. © The Author(s) 2024.
URI: https://doi.org/10.1177/87552930231211208
https://hdl.handle.net/20.500.14365/5143
ISSN: 8755-2930
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
5143.pdf7.89 MBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

8
checked on Nov 20, 2024

WEB OF SCIENCETM
Citations

7
checked on Nov 20, 2024

Page view(s)

74
checked on Nov 18, 2024

Download(s)

16
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.