Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14365/990
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Aktan, Ridvan | - |
dc.contributor.author | Yilmaz, Hayriye | - |
dc.contributor.author | Demir, Ismail | - |
dc.contributor.author | Ozalevli, Sevgi | - |
dc.date.accessioned | 2023-06-16T12:48:15Z | - |
dc.date.available | 2023-06-16T12:48:15Z | - |
dc.date.issued | 2023 | - |
dc.identifier.issn | 0021-1265 | - |
dc.identifier.issn | 1863-4362 | - |
dc.identifier.uri | https://doi.org/10.1007/s11845-022-03238-w | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14365/990 | - |
dc.description | Article; Early Access | en-US |
dc.description.abstract | Background The globalization of healthcare systems, and the aim to lower healthcare costs have all contributed to the growth of telehealth technology in recent years. However, before these systems are put into use, their efficacy should be verified. To the best of our knowledge, this is the first study focusing on the evaluation of functional exercise capacity using the 30-s sit-to-stand (30-s STS) test as a tele-assessment method in patients with type 2 diabetes mellitus (T2DM). Aims The purpose of the study is to investigate the level of agreement between tele-assessment and face-to-face assessment of 30-s STS test in patients with T2DM. Methods Fifty participants performed two times 30-s STS tests separated by 1 h: a face-to-face and an Internet-connected video call examination (tele-assessment). Two physiotherapists conduct these evaluations; each was blinded to the other. The order of the evaluations was designated at random for each participant and physiotherapist. Results There was a good level of agreement between tele-assessment and face-to-face assessment of the 30-s STS test (mean differences = 0.20 +/- 0.88, limits of agreement =1.93 to - 1.53). Excellent interrater reliability was found for scores of the 30-s STS test [ICC = 0.93 (95% CI: 0.88; 0.96)]. In addition, all before and after test parameters show that there was a very good interrater reliability (rho >= 0.75). Conclusions This study shows a good level of agreement between tele-assessment and face-to-face assessment of the 30-s STS test. Our study's findings indicate that tele-assessment is a potential application to determine the level of physical capacity remotely in patients with T2DM. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer London Ltd | en_US |
dc.relation.ispartof | Irısh Journal of Medıcal Scıence | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Physical assessment | en_US |
dc.subject | Tele-assessment | en_US |
dc.subject | Telehealth | en_US |
dc.subject | Type 2 diabetes | en_US |
dc.subject | 30-s sit-to-stand | en_US |
dc.subject | Test-Retest Reliability | en_US |
dc.subject | Physical-Activity | en_US |
dc.subject | Older-Adults | en_US |
dc.subject | Physiotherapy | en_US |
dc.subject | Validity | en_US |
dc.title | Agreement between tele-assessment and face-to-face assessment of 30-s sit-to-stand test in patients with type 2 diabetes mellitus | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1007/s11845-022-03238-w | - |
dc.identifier.pmid | 36456718 | en_US |
dc.identifier.scopus | 2-s2.0-85143222167 | en_US |
dc.department | İzmir Ekonomi Üniversitesi | en_US |
dc.authorid | Aktan, Ridvan/0000-0002-3327-461X | - |
dc.authorid | Yilmaz, Hayriye/0000-0002-1151-7190 | - |
dc.authorwosid | Aktan, Ridvan/Q-8888-2016 | - |
dc.authorscopusid | 57203551117 | - |
dc.authorscopusid | 57990920600 | - |
dc.authorscopusid | 57209138471 | - |
dc.authorscopusid | 21743831700 | - |
dc.identifier.wos | WOS:000893144300003 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q1 | - |
dc.identifier.wosquality | Q3 | - |
item.grantfulltext | reserved | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 15.09. Physiotherapy | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
4352.pdf Restricted Access | 682.7 kB | Adobe PDF | View/Open Request a copy |
CORE Recommender
SCOPUSTM
Citations
2
checked on Nov 20, 2024
WEB OF SCIENCETM
Citations
2
checked on Nov 20, 2024
Page view(s)
178
checked on Nov 18, 2024
Download(s)
6
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.