Handheld Optofluidic Platform Towards Binding Dynamics Applications in Field-Settings
| dc.contributor.author | Yaman, S. | |
| dc.contributor.author | Avci, M.B. | |
| dc.contributor.author | Kurul, F | |
| dc.contributor.author | Topkaya, S.N. | |
| dc.contributor.author | Cetin, A.E. | |
| dc.date.accessioned | 2023-10-27T06:45:13Z | |
| dc.date.available | 2023-10-27T06:45:13Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | We have introduced a lensfree optofluidic platform that incorporates subwavelength nanohole arrays, a compact microfluidics system, and on-chip computational imaging to enable label-free identification of biomolecular interactions. Our platform weighs only 260 g and has dimensions of 16 cm × 10 cm × 11 cm. It utilizes a CMOS imager to capture plasmonic diffraction field images, offering a wide field-of-view of up to 11.5 mm² for refractive index sensing. To illuminate the plasmonic chip, we employ an LED source positioned close to the transmission resonance of the nanohole arrays. This LED source creates diffraction patterns on the imager. The platform ensures the targeted delivery of analytes to the ligand-coated sensing surface using microfluidics. By analyzing real-time variations within the diffraction field images, we could reveal the time-dependent binding dynamics of biomolecules. Our platform has demonstrated an experimentally obtained limit of detection (LOD) as low as 5 ng/mL for protein IgG. Furthermore, based on the real-time diffraction field images, we successfully determine the association and disassociation constants, which account for the binding and detachment between protein A/G and IgG. We have also developed a software that allows full control of the hardware settings of the portable platform, including the camera and pump system. This software also incorporates an image-processing algorithm to calculate the binding parameters for the analytes of interest. Providing high-quality sensing capabilities in a cost-effective infrastructure, we believe that our optofluidic biosensor platform offers significant advantages for surface plasmon resonance (SPR) applications for field-settings. © 2023 Elsevier B.V. | en_US |
| dc.description.sponsorship | Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK: 118C458 | en_US |
| dc.description.sponsorship | S.Y. acknowledges The Scientific and Technological Research Council of Turkey ( TUBITAK ) 2232 – National Postdoctoral Research Fellowship (Project No. 118C458 ). | en_US |
| dc.identifier.doi | 10.1016/j.sna.2023.114685 | |
| dc.identifier.issn | 0924-4247 | |
| dc.identifier.scopus | 2-s2.0-85172724074 | |
| dc.identifier.uri | https://doi.org/10.1016/j.sna.2023.114685 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14365/4933 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier B.V. | en_US |
| dc.relation.ispartof | Sensors and Actuators A: Physical | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Computational imaging | en_US |
| dc.subject | Label-free biosensing | en_US |
| dc.subject | Lensfree imaging | en_US |
| dc.subject | Microfluidics | en_US |
| dc.subject | Plasmonics | en_US |
| dc.subject | Computational Imaging | en_US |
| dc.subject | Cost effectiveness | en_US |
| dc.subject | Diffraction | en_US |
| dc.subject | Image processing | en_US |
| dc.subject | Light emitting diodes | en_US |
| dc.subject | Plasmonics | en_US |
| dc.subject | Proteins | en_US |
| dc.subject | Refractive index | en_US |
| dc.subject | Surface plasmon resonance | en_US |
| dc.subject | Analytes | en_US |
| dc.subject | Binding dynamics | en_US |
| dc.subject | Computational imaging | en_US |
| dc.subject | Diffraction fields | en_US |
| dc.subject | Field images | en_US |
| dc.subject | Label-free biosensing | en_US |
| dc.subject | Lensfree imaging | en_US |
| dc.subject | Nanohole arrays | en_US |
| dc.subject | Opto-fluidics | en_US |
| dc.subject | Plasmonics | en_US |
| dc.subject | Microfluidics | en_US |
| dc.title | Handheld Optofluidic Platform Towards Binding Dynamics Applications in Field-Settings | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.institutional | … | |
| gdc.author.scopusid | 57188820254 | |
| gdc.author.scopusid | 58242821000 | |
| gdc.author.scopusid | 58617032100 | |
| gdc.author.scopusid | 36612616900 | |
| gdc.author.scopusid | 35291427500 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.access | metadata only access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Ekonomi Üniversitesi | en_US |
| gdc.description.departmenttemp | Yaman, S., Izmir Biomedicine and Genome Center, Izmir, Balcova, 35340, Turkey, Department of Radiology, Stanford University, Palo Alto, CA 94304, United States; Avci, M.B., Izmir Biomedicine and Genome Center, Izmir, Balcova, 35340, Turkey, Department of Electrical and Electronics Engineering, Izmir University of Economics, Balcova, Izmir, 35330, Turkey; Kurul, F., Izmir Biomedicine and Genome Center, Izmir, Balcova, 35340, Turkey, Izmir International Biomedicine and Genome Institute, Dokuz Eylul University, Balcova, Izmir, 35340, Turkey; Topkaya, S.N., Department of Analytical Chemistry, Faculty of Pharmacy, Izmir Katip Celebi University, Cigli, Izmir, 35620, Turkey; Cetin, A.E., Izmir Biomedicine and Genome Center, Izmir, Balcova, 35340, Turkey | en_US |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | Q1 | |
| gdc.description.volume | 363 | en_US |
| gdc.description.wosquality | Q1 | |
| gdc.identifier.openalex | W4386997598 | |
| gdc.identifier.wos | WOS:001097592100001 | |
| gdc.index.type | WoS | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 1.0 | |
| gdc.oaire.influence | 2.528495E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.popularity | 2.803605E-9 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 02 engineering and technology | |
| gdc.oaire.sciencefields | 0210 nano-technology | |
| gdc.oaire.sciencefields | 01 natural sciences | |
| gdc.oaire.sciencefields | 0104 chemical sciences | |
| gdc.openalex.collaboration | International | |
| gdc.openalex.fwci | 0.1126 | |
| gdc.openalex.normalizedpercentile | 0.41 | |
| gdc.opencitations.count | 1 | |
| gdc.plumx.mendeley | 3 | |
| gdc.plumx.scopuscites | 2 | |
| gdc.scopus.citedcount | 2 | |
| gdc.wos.citedcount | 2 | |
| relation.isOrgUnitOfPublication | e9e77e3e-bc94-40a7-9b24-b807b2cd0319 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | e9e77e3e-bc94-40a7-9b24-b807b2cd0319 |
Files
Original bundle
1 - 1 of 1