An Automatic Level Set Based Liver Segmentation From Mri Data Sets

Loading...
Publication Logo

Date

2012

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Top 10%
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

A fast and accurate liver segmentation method is a challenging work in medical image analysis area. Liver segmentation is an important process for computer-assisted diagnosis, pre-evaluation of liver transplantation and therapy planning of liver tumors. There are several advantages of magnetic resonance imaging such as free form ionizing radiation and good contrast visualization of soft tissue. Also, innovations in recent technology and image acquisition techniques have made magnetic resonance imaging a major tool in modern medicine. However, the use of magnetic resonance images for liver segmentation has been slow when we compare applications with the central nervous systems and musculoskeletal. The reasons are irregular shape, size and position of the liver, contrast agent effects and similarities of the gray values of neighbor organs. Therefore, in this study, we present a fully automatic liver segmentation method by using an approximation of the level set based contour evolution from T2 weighted magnetic resonance data sets. The method avoids solving partial differential equations and applies only integer operations with a two-cycle segmentation algorithm. The efficiency of the proposed approach is achieved by applying the algorithm to all slices with a constant number of iteration and performing the contour evolution without any user defined initial contour. The obtained results are evaluated with four different similarity measures and they show that the automatic segmentation approach gives successful results. © 2012 IEEE.

Description

University of Evry Val d'Essonne (UEVE);Istanbul Aydin Universitesi (IAU);Inst. Technol. Univ. Evry Val Essonne (IUT);Informatics, Biol. Integr. Complex Syst. Lab. (IBISC);Montpellier Lab. Informatics, Rob., Microelectron. (LIRMM)
2012 3rd International Conference on Image Processing Theory, Tools and Applications, IPTA 2012 -- 15 October 2012 through 18 October 2012 -- Istanbul -- 96361

Keywords

Geometric active contours, Level set method, Liver segmentation, MRI, Automatic segmentations, Central nervous systems, Computer assisted diagnosis, Geometric active contours, Level Set method, Liver segmentation, Magnetic resonance images, Segmentation algorithms, Ionizing radiation, Iterative methods, Magnetic resonance imaging, Numerical methods, Partial differential equations, Tissue, Image segmentation, Segmentation algorithms, Ionizing radiation, Automatic segmentations, Image segmentation, Tissue, Iterative methods, Liver segmentation, Level Set method, Partial differential equations, Magnetic resonance images, Computer assisted diagnosis, Central nervous systems, Magnetic resonance imaging, Liver segmentation; MRI; Geometric active contours; Level set method, Level set method, Numerical methods, Geometric active contours, MRI

Fields of Science

02 engineering and technology, 03 medical and health sciences, 0302 clinical medicine, 0202 electrical engineering, electronic engineering, information engineering

Citation

WoS Q

N/A

Scopus Q

N/A
OpenCitations Logo
OpenCitations Citation Count
17

Source

2012 3rd International Conference on Image Processing Theory, Tools and Applications, IPTA 2012

Volume

Issue

Start Page

192

End Page

197
PlumX Metrics
Citations

CrossRef : 3

Scopus : 43

Captures

Mendeley Readers : 25

SCOPUS™ Citations

43

checked on Mar 17, 2026

Downloads

23

checked on Mar 17, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.0982

Sustainable Development Goals

SDG data is not available