Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14365/2538
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Demirhan, Alper | - |
dc.contributor.author | Eksin, Ece | - |
dc.contributor.author | Kilic, Yalin | - |
dc.contributor.author | Erdem, Arzum | - |
dc.date.accessioned | 2023-06-16T14:41:02Z | - |
dc.date.available | 2023-06-16T14:41:02Z | - |
dc.date.issued | 2022 | - |
dc.identifier.issn | 2072-666X | - |
dc.identifier.uri | https://doi.org/10.3390/mi13101610 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.14365/2538 | - |
dc.description.abstract | A handheld USB-powered instrument developed for the electrochemical detection of nucleic acids and biomolecular interactions is presented. The proposed instrument is capable of scanning +/- 2.25 V while measuring currents up to +/- 10 mA, with a minimum current resolution of 6.87 pA. Therefore, it is suitable for nucleic acid sensors, which have high background currents. A low-cost microcontroller with an on-chip 16-bit analog-to-digital converter, 12-bit digital-to-analog converter, and a built-in USB controller were used to miniaturize the system. The offset voltages and gain errors of the analog peripherals were calibrated to obtain a superior performance. Thus, a similar performance to those of the market-leader potentiostats was achieved, but at a fraction of their cost and size. The performance of the application of this proposed architecture was tested successfully and was found to be similar to a leading commercial device through a clinical application in the aspects of the detection of nucleic acids, such as calf thymus ssDNA and dsDNA, and their interactions with a protein (BSA) by using single-use graphite electrodes in combination with the differential pulse voltammetry technique. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Mdpi | en_US |
dc.relation.ispartof | Mıcromachınes | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | potentiostat | en_US |
dc.subject | differential pulse voltammetry | en_US |
dc.subject | point-of-care testing | en_US |
dc.subject | Dna | en_US |
dc.subject | Protein | en_US |
dc.title | Low-Cost High-Resolution Potentiostat for Electrochemical Detection of Nucleic Acids and Biomolecular Interactions | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3390/mi13101610 | - |
dc.identifier.pmid | 36295963 | en_US |
dc.identifier.scopus | 2-s2.0-85140851216 | en_US |
dc.department | İzmir Ekonomi Üniversitesi | en_US |
dc.authorid | Erdem, Arzum/0000-0002-4375-8386 | - |
dc.authorid | Eksin, Ece/0000-0001-7175-2857 | - |
dc.authorwosid | Erdem, Arzum/X-1925-2019 | - |
dc.authorscopusid | 57212485719 | - |
dc.authorscopusid | 55845006300 | - |
dc.authorscopusid | 57212488581 | - |
dc.authorscopusid | 7004459748 | - |
dc.identifier.volume | 13 | en_US |
dc.identifier.issue | 10 | en_US |
dc.identifier.wos | WOS:000873066700001 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q2 | - |
dc.identifier.wosquality | Q2 | - |
item.grantfulltext | open | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 05.02. Biomedical Engineering | - |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
3
checked on Nov 20, 2024
WEB OF SCIENCETM
Citations
3
checked on Nov 20, 2024
Page view(s)
88
checked on Nov 18, 2024
Download(s)
30
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.