Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14365/2538
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDemirhan, Alper-
dc.contributor.authorEksin, Ece-
dc.contributor.authorKilic, Yalin-
dc.contributor.authorErdem, Arzum-
dc.date.accessioned2023-06-16T14:41:02Z-
dc.date.available2023-06-16T14:41:02Z-
dc.date.issued2022-
dc.identifier.issn2072-666X-
dc.identifier.urihttps://doi.org/10.3390/mi13101610-
dc.identifier.urihttps://hdl.handle.net/20.500.14365/2538-
dc.description.abstractA handheld USB-powered instrument developed for the electrochemical detection of nucleic acids and biomolecular interactions is presented. The proposed instrument is capable of scanning +/- 2.25 V while measuring currents up to +/- 10 mA, with a minimum current resolution of 6.87 pA. Therefore, it is suitable for nucleic acid sensors, which have high background currents. A low-cost microcontroller with an on-chip 16-bit analog-to-digital converter, 12-bit digital-to-analog converter, and a built-in USB controller were used to miniaturize the system. The offset voltages and gain errors of the analog peripherals were calibrated to obtain a superior performance. Thus, a similar performance to those of the market-leader potentiostats was achieved, but at a fraction of their cost and size. The performance of the application of this proposed architecture was tested successfully and was found to be similar to a leading commercial device through a clinical application in the aspects of the detection of nucleic acids, such as calf thymus ssDNA and dsDNA, and their interactions with a protein (BSA) by using single-use graphite electrodes in combination with the differential pulse voltammetry technique.en_US
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.ispartofMıcromachınesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectpotentiostaten_US
dc.subjectdifferential pulse voltammetryen_US
dc.subjectpoint-of-care testingen_US
dc.subjectDnaen_US
dc.subjectProteinen_US
dc.titleLow-Cost High-Resolution Potentiostat for Electrochemical Detection of Nucleic Acids and Biomolecular Interactionsen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/mi13101610-
dc.identifier.pmid36295963en_US
dc.identifier.scopus2-s2.0-85140851216en_US
dc.departmentİzmir Ekonomi Üniversitesien_US
dc.authoridErdem, Arzum/0000-0002-4375-8386-
dc.authoridEksin, Ece/0000-0001-7175-2857-
dc.authorwosidErdem, Arzum/X-1925-2019-
dc.authorscopusid57212485719-
dc.authorscopusid55845006300-
dc.authorscopusid57212488581-
dc.authorscopusid7004459748-
dc.identifier.volume13en_US
dc.identifier.issue10en_US
dc.identifier.wosWOS:000873066700001en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
dc.identifier.wosqualityQ2-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.fulltextWith Fulltext-
item.languageiso639-1en-
crisitem.author.dept05.02. Biomedical Engineering-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
2538.pdf1.98 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Oct 2, 2024

WEB OF SCIENCETM
Citations

3
checked on Oct 2, 2024

Page view(s)

88
checked on Sep 30, 2024

Download(s)

20
checked on Sep 30, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.