Quantitative Determination of H2o2 for Detection of Alanine Aminotransferase Using Thin Film Electrodes

Loading...
Publication Logo

Date

2020

Journal Title

Journal ISSN

Volume Title

Publisher

Academic Press Inc Elsevier Science

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

The abnormal concentrations or absence of biomolecules (e.g., proteins) in blood can further be used in diagnosis of a particular pathology at an early stage. Current studies are intensely focusing on the analysis of interaction and detection of biomolecules via point-of-care systems (POCs), allowing miniaturized and parallelized reactions, simultaneously. Recent developments have shown that the collaboration of electrochemical sensing techniques and POCs to overcome challenging problems in health-care settings provides new approaches in diagnosis and treatment of diseases. The aim of this study was to adapt the alanine aminotransferase (ALT) enzyme to the platinum (Pt) thin film electrode system and quantitatively determine the enzyme levels via enzymatically generated H2O2 with differential pulse voltammetry (DPV). A simple potentiostat architecture with expanded sweep range utilizing dual LMP91000 devices was developed and adapted to the needs of the biosensor. In order to calibrate the system, known concentrations of H2O2 were also tested. Moreover, signals associated with the other electroactive species coming from the ALT reaction were eliminated. Resulted potential range has been achieved between +500 mV and + 900 mV and the linear range was found to be 0.05 M-0.5 M for H2O2, whereas 5 UL-1 to 120 UL-1 for ALT enzyme.

Description

Keywords

Alanine aminotransferase, Differential pulse voltammetry, Electrochemical sensing, Hydrogen peroxide, Potentiostat, Thin-film electrodes, Aspartate-Aminotransferase, Electrochemical Biosensor, Point, Glutamate, Choline, Sensors, Systems, Future, Vitro, Array, Potentiostat, Swine, Differential pulse voltammetry, Alanine Transaminase, Biosensing Techniques, Electrochemical Techniques, Hydrogen Peroxide, Hydrogen peroxide, Point-of-Care Testing, Electrochemical sensing, Alanine aminotransferase, Animals, Thin-film electrodes, Electrodes, Platinum

Fields of Science

04 agricultural and veterinary sciences, 02 engineering and technology, 01 natural sciences, 0104 chemical sciences, 0404 agricultural biotechnology, 0405 other agricultural sciences, 0210 nano-technology

Citation

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
17

Source

Analytıcal Bıochemıstry

Volume

591

Issue

Start Page

113538

End Page

PlumX Metrics
Citations

CrossRef : 18

Scopus : 22

PubMed : 3

Captures

Mendeley Readers : 33

SCOPUS™ Citations

22

checked on Feb 13, 2026

Web of Science™ Citations

21

checked on Feb 13, 2026

Page Views

1

checked on Feb 13, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.82440806

Sustainable Development Goals

SDG data is not available