Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14365/1037
Title: Quantitative determination of H2O2 for detection of alanine aminotransferase using thin film electrodes
Authors: Saygili, Ecem
Orakci, Beyza
Koprulu, Melisa
Demirhan, Alper
Ilhan-Ayisigi, Esra
Kilic, Yalin
Yesil-Celiktas, Ozlem
Keywords: Alanine aminotransferase
Differential pulse voltammetry
Electrochemical sensing
Hydrogen peroxide
Potentiostat
Thin-film electrodes
Aspartate-Aminotransferase
Electrochemical Biosensor
Point
Glutamate
Choline
Sensors
Systems
Future
Vitro
Array
Publisher: Academic Press Inc Elsevier Science
Abstract: The abnormal concentrations or absence of biomolecules (e.g., proteins) in blood can further be used in diagnosis of a particular pathology at an early stage. Current studies are intensely focusing on the analysis of interaction and detection of biomolecules via point-of-care systems (POCs), allowing miniaturized and parallelized reactions, simultaneously. Recent developments have shown that the collaboration of electrochemical sensing techniques and POCs to overcome challenging problems in health-care settings provides new approaches in diagnosis and treatment of diseases. The aim of this study was to adapt the alanine aminotransferase (ALT) enzyme to the platinum (Pt) thin film electrode system and quantitatively determine the enzyme levels via enzymatically generated H2O2 with differential pulse voltammetry (DPV). A simple potentiostat architecture with expanded sweep range utilizing dual LMP91000 devices was developed and adapted to the needs of the biosensor. In order to calibrate the system, known concentrations of H2O2 were also tested. Moreover, signals associated with the other electroactive species coming from the ALT reaction were eliminated. Resulted potential range has been achieved between +500 mV and + 900 mV and the linear range was found to be 0.05 M-0.5 M for H2O2, whereas 5 UL-1 to 120 UL-1 for ALT enzyme.
URI: https://doi.org/10.1016/j.ab.2019.113538
https://hdl.handle.net/20.500.14365/1037
ISSN: 0003-2697
1096-0309
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
42.pdf
  Restricted Access
1.63 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

15
checked on Oct 2, 2024

WEB OF SCIENCETM
Citations

15
checked on Oct 2, 2024

Page view(s)

60
checked on Sep 30, 2024

Download(s)

6
checked on Sep 30, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.