Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14365/1037
Title: | Quantitative determination of H2O2 for detection of alanine aminotransferase using thin film electrodes | Authors: | Saygili, Ecem Orakci, Beyza Koprulu, Melisa Demirhan, Alper Ilhan-Ayisigi, Esra Kilic, Yalin Yesil-Celiktas, Ozlem |
Keywords: | Alanine aminotransferase Differential pulse voltammetry Electrochemical sensing Hydrogen peroxide Potentiostat Thin-film electrodes Aspartate-Aminotransferase Electrochemical Biosensor Point Glutamate Choline Sensors Systems Future Vitro Array |
Publisher: | Academic Press Inc Elsevier Science | Abstract: | The abnormal concentrations or absence of biomolecules (e.g., proteins) in blood can further be used in diagnosis of a particular pathology at an early stage. Current studies are intensely focusing on the analysis of interaction and detection of biomolecules via point-of-care systems (POCs), allowing miniaturized and parallelized reactions, simultaneously. Recent developments have shown that the collaboration of electrochemical sensing techniques and POCs to overcome challenging problems in health-care settings provides new approaches in diagnosis and treatment of diseases. The aim of this study was to adapt the alanine aminotransferase (ALT) enzyme to the platinum (Pt) thin film electrode system and quantitatively determine the enzyme levels via enzymatically generated H2O2 with differential pulse voltammetry (DPV). A simple potentiostat architecture with expanded sweep range utilizing dual LMP91000 devices was developed and adapted to the needs of the biosensor. In order to calibrate the system, known concentrations of H2O2 were also tested. Moreover, signals associated with the other electroactive species coming from the ALT reaction were eliminated. Resulted potential range has been achieved between +500 mV and + 900 mV and the linear range was found to be 0.05 M-0.5 M for H2O2, whereas 5 UL-1 to 120 UL-1 for ALT enzyme. | URI: | https://doi.org/10.1016/j.ab.2019.113538 https://hdl.handle.net/20.500.14365/1037 |
ISSN: | 0003-2697 1096-0309 |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
42.pdf Restricted Access | 1.63 MB | Adobe PDF | View/Open Request a copy |
CORE Recommender
SCOPUSTM
Citations
16
checked on Nov 20, 2024
WEB OF SCIENCETM
Citations
16
checked on Nov 20, 2024
Page view(s)
66
checked on Nov 18, 2024
Download(s)
6
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.